廣告

2024 年 3 月
 123
45678910
11121314151617
18192021222324
25262728293031

彙整

ESXi Server線上升級

參考網址:https://medium.com/@jackyu/%E5%8D%87%E7%B4%9A-esxi-6-5-%E5%88%B0-esxi-6-7-613e39d6dccb

SSH連入

打開防火牆

esxcli network firewall ruleset set -e true -r httpClient

撈一下線上可更新列表(查詢6.7版) esxcli software sources profile list -d https://hostupdate.vmware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml | grep -i ESXi-6.7

===================

[root@CS-ESXi-49:~] esxcli software sources profile list -d https://hostupdate.v

mware.com/software/VUM/PRODUCTION/main/vmw-depot-index.xml | grep -i ESXi-6.7

ESXi-6.7.0-20191201001s-no-tools VMware, Inc. PartnerSupported 2020-08-08T04: 12:43 2020-08-08T04:12:43

ESXi-6.7.0-20190802001-standard VMware, Inc. PartnerSupported 2020-08-08T04: 12:43 2020-08-08T04:12:43

ESXi-6.7.0-20190401001s-no-tools VMware, Inc. PartnerSupported 2020-08-08T04: 12:43 2020-08-08T04:12:43

ESXi-6.7.0-20200804001-standard VMware, […]

[教學] 降級 VMware 虛擬機器的 Hardware compatibility 的 Level

出處 https://blog.hy31.net/2014/12/vmware-hardware-compatibility-level.html

[教學] 降級 VMware 虛擬機器的 Hardware compatibility 的 Level 起因:目前VMware的軟體的版本很多,然後用新版軟體所產生的VMDK又會不能給舊版使用

EX:在 VMware Workstation 9、10所產生的VMDK是無法在 ESXI 5.1正常使用的

所以,以下是教你怎麼把現有新版的產生出相容舊版的使用

目前現有VMDK是相容 Workstation 10 版本

在你要用的機器按右鍵,選擇Manage,然後Change Hardware Compatibility

皆下來就是照著精靈作

然後在這頁面請確定你跟要的系統跟版本,然後請記得 ESXI 5.1 是跟 Workstaion 8 相容

這邊是選擇你要將降版過後的虛擬機另存新檔還是覆寫

然後就是開始系統的處理

最後完成後就是降版成功

ESXi 6.7 host UTC 本機時區非UTC+8問題

用SSH連入ESXi Server輸入date指令,你會發現時間跟vSphere Client的時間不一致,原因是UTC問題,詳細可以看這篇

https://blog.51cto.com/jdonghong/1957118

先在本機電腦建立下面檔案,用WinSCP連入ESXi Server,把檔案放在ESXi Server的localdisk內

建立smtp.xml檔案(開放STMP 25讓ghettoVCB備份程式可以發信通知結果) ===================================== < !– E-MAIL SMTP –>   < ConfigRoot>    <service id=’1000′>      <id>SMTP</id>      <rule>        <direction>outbound</direction>        <protocol>tcp</protocol>        <porttype>dst</porttype>        <port>25</port>      </rule>      <enabled>true</enabled>      <required>false</required>    </service>  < /ConfigRoot>  =====================================

建立root檔案(使用ghettoVCB備份方式排程用,可GOOGLE一下用法) ===================================== […]

vCenter SQL無法啟動與vSphere Client 的 Hardware Status 與 Service Status異常

今早發現SQL啟動不了,vCenter也跟著啟動不了,跟最早發現問題一樣,之前我是回朔備份解決此問題,但今天發現是自動更新SQL20018 SP4後會發生這樣的問題,現在把系統再回朔一次,停止WSUS更新SQL2008 SP4………..

更新前:

更新後

======================== 原先安裝版本為VMware-VIMSetup-all-5.1.0-2308386.iso,出問題後也重新安裝過VMware-VIMSetup-all-5.1.0-2308386.iso還是一樣沒解決。 剛下載目前最新的版本直接更新重啟SERVER後,再連到SERVER抓vSphere Client最新版更新在個人電腦上,就全癒了。 VMware-VIMSetup-all-5.1.0-3900744.iso ========================= 這張是個人電腦上執行vSphere Client會出錯。 這張是在vSphere Server上執行vSphere Client就沒問題。 […]

Levono X3650 M5 + 美光MX200 500G SSD * 12 Raid 5 在ESXi上跑WIN7簡易測試

SSD SAS 900G 萬轉 * 4 RAID 5(忘了存到IOPS,因為跑太久懶的重跑) 看測試數據是快很多,沒買fastpath……

ESXI5.5U3 INSTALL FAIL ON NEW X3650 M5 – FAILED TO RESOLVE CIRCULAR RELOCATION

新買的Levono X3650 M5 Server 安裝ESXi 5.1 U3 一半時出現 FAILED TO RESOLVE CIRCULAR RELOCATION,查了一下資料,發現有人有一樣的問題,測試後真的可以安裝,只是不知安裝完後需不需要改回BIOS設定值?

=======================

https://kitkatneko.wordpress.com/2015/06/10/esxi5-5u2-install-fail-on-new-x240-m5-failed-to-resolve-circular-relocation/

ESXI5.5U2 INSTALL FAIL ON NEW X240 M5 – FAILED TO RESOLVE CIRCULAR RELOCATION

Posted on 10/06/2015 by kitkatneko

The other day I ran into a strange issue. Just received a bunch of Flex Blade x240 for a Vmware cluster and trying to get ESXi installed […]

VM ESXi Server DirectPath I/O Passthrough RAID卡後無法取消問題

測試把RAID卡在ESXi Server下做passthrough,結果怎樣取消重開機還是套用中……….LOCALDISK回不來,傻眼………

試過很多方式都不能解決,最後只有這方式可以解決

1. Insert the CDROM in the Server. 2. Boot the Server from the CDROM 3. Following the installation on screen. 4. When prompted to PRESERVE the VMFS datastore – select YES. 5. Complete a new installation. in […]

20150225-ASUS BM1AD網卡不支援ESXi手動安裝驅動

下載Intel® Ethernet Connection I217-V, e1000e driver

http://shell.peach.ne.jp/~aoyama/wordpress/download/net-e1000e-2.3.2.x86_64.vib

用Winscp 把vib丟進去 esxi tmp目錄內

net-e1000e-2.3.2.x86_64.vib

SSH 登入 在ESXI下

cd /usr/bin

執行esxcli software acceptance set –level=CommunitySupported

成功轉換Host acceptance level changed to ‘CommunitySupported’.

執行esxcli software vib install -v /tmp/net-e1000e-2.3.2.x86_64.vib

成功安裝

Installation Result

Message: The update completed successfully, but the system needs to be rebooted for the changes to be effective.

Reboot Required: true

VIBs Installed: daoyama_bootbank_net-e1000e_2.3.2

VIBs Removed: VMware_bootbank_net-e1000e_1.1.2-3vmw.510.2.23.1483097

VIBs Skipped:

安裝好後Reboot

====================

參考:

http://www.ivobeerens.nl/2013/09/20/enable-the-intel-i217-v-network-card-in-vmware-esxi/

http://blog.kihltech.com/2014/01/how-to-add-intel-nic-drivers-to-an-esxi-5-5-iso/

IBM3650M3-Raid5測試Strip size與ESXi傳輸大檔關係

測試環境:

CPU:Intel E5620 2.4G * 2

RAM:28G

作業系統:ESXi 5.1 – 1483097

硬碟:Raid5 – SAS 2.5 300G 10000轉*8

Raid卡:ServerRaid M5014

Write Back:開

Disk Cache:開

Read-ahead:開

測試方式:用vSphere Client連入ESXi Server直接開啟LocalDisk(Raid5) Databases傳送PC上的600MB ISO檔案。

Raid Strip size:

256K => 2~7MB游走

128K => 30~37MB 游走

64K => 2~7遊走

對於傳送固定大檔,簡易測試後Strip size於256k 128k 64k在128K下有最好的傳輸效果。

使用VT-D技術注意事項

使用VT-D技術注意事項:

使用後的VM會無法使用CLONE與Migrate移轉功能,因為綁住PCIe裝置。

1. 因TemperUSB溫度器無法直接被ESXi Server抓取辨識,故買了張伽利略PCIe擴充USB卡安裝在HP ML150 G6 Server上,ESXi Server設定直接存取該裝置(使用INTEL VT-D技術,只能用在擴充介面卡上)

建立Win7 VM後新增PCI裝置

開機進WIN7後再安裝Driver即可直接存取PCIe擴充USB卡。